Summary / Purpose
Use this article to set up a Zebra TC501 handheld scanner (PDA) so that barcode scans go straight into the Transvirtual app.
The settings are made in Zebra's DataWedge app, which controls how the scanner sends barcode data to other apps on the device.
Overview
- Out of the box, the scanner sends barcodes as typed text (keystrokes). The Transvirtual app needs the scan sent as an "intent" instead.
- You change this once per device, in the default DataWedge profile.
- These settings were tested on the Zebra TC501 with Transvirtual app version 1.6.6.
Before you begin
- Make sure the Transvirtual app is installed on the device and you can log in.
- You need access to the device's apps list to open DataWedge.
How To
Configure DataWedge
- On the device, open the DataWedge app.
- Select Profile0 (default).
- Make sure Keystroke output is turned off.
- Make sure Intent output is turned on.
- Set Intent delivery to Broadcast intent.
Under Intent output, open Basic data formatting and tick all three of:
- Enable
- Send data
- Send ENTER key
- Make sure IP output is turned off.
- Open the Transvirtual app and scan a barcode to check that it comes through.

The order you change these settings in doesn't matter. What matters is that the profile ends up matching the settings above.
Troubleshooting
Nothing happens when I scan in the Transvirtual app
Open DataWedge and check Profile0 (default) again. Intent output must be on with Intent delivery set to Broadcast intent, and Keystroke output must be off.
The barcode scans but the screen doesn't move on to the next step
Check that Send ENTER key is ticked under Intent output > Basic data formatting.
The barcode appears twice, or appears in the wrong field
Keystroke output is probably still on, so the scan is being sent both as typed text and as an intent. Turn Keystroke output off.